Aitecs 2016
November 26, 2018The aitecs 2017 Syringe Pump
is an advanced, configurable and versatile syringe pump offering enhanced safety in all clinical environments. The common user interface across the aitecs Advanced Syringe Pump range promotes ease of use and simplifies device training needs.
The aitecs 2017 Syringe Pump
can be used as a stand‑alone device or be stacked together with other aitecs Infusion Docking Station providing connectivity compatible with the aitecs pumps on the aitecs Infusion Management System, Patient Data Management Systems (PDMS) and/or Hospital Information Systems (HIS) via the open system architecture.
Safety, Reliability and Flexibility
Advanced Syringe Pump
aitecs® 2017 Syringe Pump specifications
Flow Rate Range 0.01-9.999 mL/h in 0.001 mL/h steps
10.0-99.99 mL/h in 0.01 mL/h steps
100.0-999.9 mL/h in 0.1 mL/h steps
1000-2200 mL/h in 1 mL/h steps
Volumetric Accuracy ±2 % (according to EN 60601-2-24)
Syringe Sizes 2/3 mL, 5/6 mL, 10/12 mL, 20/22 mL, 30/35 mL, 50/60 mL
(all major brands, additional brands upon agreement)
Infusion Modes Continuous
Volume Over Time
Dose Over Time Intermittent
Total Parenteral Nutrition (TPN)
Dose Units g, mg, mcg, ng, Units, kUnits, mUnits, mcUnits, mol, mmol,
mcmol, mEq, and other configured by the medical personnel
Occlusion Alarm Up to 10 levels
Rapid Occlusion Less than 5 min at High sensitivity level
Detection (ROD) (at 1 mL/h with 60 mL syringe)
Restart After Occlusion 0-3 (configurable)
Prime Rates 1-100 mL/h (2/3 mL syringes)
1-125 mL/h (5/6 mL syringes)
1-325 mL/h (10/12 mL syringes)
1-600 mL/h (20/22 mL, 30/35 mL and 50/60 mL syringes)
Bolus Volume Limit 1-100 % of syringe size or
0.01-99.99 mL (configurable)
Bolus Rate Range 10.01-9.999 mL/h in 0.001 mL/h steps
10.0-99.99 mL/h in 0.01 mL/h steps
100.0-999.0 mL/h in 0.1 mL/h steps
1000-2200 mL/h in 1 mL/h steps
KVO Volume 0.1-10 % of the syringe volume or OFF (configurable)
KVO Rate Range 0.10-5.00 mL/h (configurable)
Volume To Be Infused 0.1-999.9 mL in 0.1 mL steps
Infusion Time 00:01-200:00 (HH:mm)
Volume Limit 0.1-999.9 mL
Post VTBI action Stop and KVO
Standby Time 00:01-23:59 (HH:mm)
Delayed Start 0:01-06:00 (HH:mm)
Dose Error < 1500 unique drug entries with nested limits available, arranged in up to 30 Profiles
Reduction Software with up to 15 Categories with up to 40 Drugs (up to 75 Drug Advisories)
Near End Of 3-120 min or 1-50 mL (to end of infusion or syringe empty)
Infusion alarm
Maximum Volume under Single Fault Condition < 0.5 mL
A Alarm Loudness 5 Levels
Warnings Syringe Empty – KVO
xx mL/min to End of Infusion
Standby Time Elapsed End of Infusion – KVO No Mains
Low Battery
Pressure Decreasing
xx mL/min to Syringe Empty
Pressure Increasing
(Medium Priority)